Using a Thermal Camera to Record the Temperature Rise as a Composite is Light Cured in a Tooth
Просмотров 22814 дней назад
Using a Thermal Camera to Record the Temperature Rise as a Composite is Light Cured in a Tooth
Irradiance vs.Power from the Curing Light
Просмотров 62Месяц назад
This video compares the irradiance measured from a curing light with the measured power. It can be seen that a curing light that is measured to have a high irradiance value does not always have a high power output. This is because the irradiance is calculated from the power/the tip area, and determining the active tip area is not always easy.
Demonstrando a diferença entre potência e irradiância
Просмотров 43Месяц назад
Nesse vídeo comparamos a potência de um fotopolimerizador com a irradiância. Pode-se observar que nem sempre um fotopolimerizador que possui uma alta irradiância possui uma alta potência.
Diferenças entre diversos Radiômetros
Просмотров 31Месяц назад
Nesse vídeo comparamos vários radiômetros de diferentes marcas com dois fotopolimerizadores. Podemos observar que o Blurphase Meter II mostrou a potência dos fotopolimerizadores e os outros dois radiômetros mostraram diferentes valores de irradiância. O que eles mostram?
Differences between the outputs from several radiometers
Просмотров 35Месяц назад
This video uses several radiometers from different brands to measure two curing lights. You can see that the Blurphase Meter II can report the power of the curing lights and the other two radiometers showed rather different values. Which one tells you how powerful the lights are?
Is Bluephase accurate? Bluephase Meter II Compared to the MiniGig
Просмотров 45Месяц назад
This video uses two lights to compare Ivoclar's Bluephase Meter II with Ultradent's MiniGig. As you can see, the Bluephase Meter II is an accurate power meter. Note that measuring the radiant power from the curing light is a much better way than reporting the irradiance due to the vagaries of determining the active light tip area (irradiance= power/area)
O Radiômetro Bluephase Meter II é preciso? Comparação entre Bluephase Meter II e MiniGig/Ultradent
Просмотров 27Месяц назад
Nesse vídeo comparamos o Bluephase Meter II da Ivoclar com o MiniGig da Ultradent e concluímos que o Bluephase Meter II é um radiômetro preciso.
Fotopolimerizando uma resina composta com fotopolimerizadores com pontas de tamanhos diferentes
Просмотров 102Месяц назад
Este vídeo demonstra o efeito da fotopolimerização de um disco composto do mesmo tamanho que a dimensão mésio-distal de um molar inferior por 10 s com uma luz fotopolimerizadora de ponta pequena e grande. Observe que a pequena ponta de luz não cobre totalmente o compósito. Após a imersão em acetona, a pequena ponta de luz não cura muito bem o compósito além da ponta de luz. Isso acontece tanto ...
Medindo a potência de fotopolimerizadores usando o Bluephase Meter II
Просмотров 532 месяца назад
Nesse vídeo mostramos a diferença na potência de 4 diferentes fotopolimerizadores utilizando o mesmo radiômetro para todas as medições: Bluephase Meter II.
Radiômetros podem não ser precisos, mas podem ser uma boa escolha para monitorar o fotopolimerizador
Просмотров 292 месяца назад
Nesse vídeo diferentes radiômetros foram comparados para mostrar a variação nos resultados de irradiância desses dispositivos. Porém é importante frisar que apesar das variações, o radiômetro é um bom método para monitoramento de fotopolimerizadores.
Demonstrando os diferentes tamanhos de ponta ativa entre o Quazar (FGM) e o Valo X (Ultradent)
Просмотров 1602 месяца назад
Esse vídeo exemplifica a diferença em relação ao tamanho da ponta ativa de diferentes fotopolimerizadores. Tanto o Quazar quanto o Valo X emitem luz azul e violeta, porém há uma diferença em relação ao tamanho da ponteira.
Demonstrando as diferenças entre o Valo Cordless, Valo Grand e Valo X
Просмотров 912 месяца назад
Nesse vídeo comparamos o tamanho da ponteira de diferentes fotopolimerizadores Valo disponíveis para compra: Valo Cordless, Valo Grand e Valo X.
Demonstrando tamanhos de ponta e emissão espectral de diferentes fotopolimerizadores
Просмотров 442 месяца назад
Esse vídeo mostra uma comparação entre tamanho da ponteira e emissão de luz de três fotopolimerizadores. Um emite apenas luz azul, um emite luz azul e uma pequena quantidade de luz violeta e o último emite grande quantidade de luz azul e violeta.
Effect of light-curing a composite with small and large tip curing lights
Просмотров 842 месяца назад
This video demonstrates the effect of light-curing a composite disc that is the same size as the mesio-distal dimension of a mandibular molar for 10 s with a small and a large tip curing light. Note that the small light tip does not fully cover the composite. After immersion in acetone, the small light tip does not cure the composite very well beyond the light tip. This happens both at the top ...
Output from the Valo Cordless, Valo Grand and Valo X
Просмотров 732 месяца назад
Output from the Valo Cordless, Valo Grand and Valo X
The different tip sizes of the Quazar from FGM and the Valo X from Ultradent
Просмотров 792 месяца назад
The different tip sizes of the Quazar from FGM and the Valo X from Ultradent
Look at the different tip diameters and emission spectra from 3 curing lights
Просмотров 692 месяца назад
Look at the different tip diameters and emission spectra from 3 curing lights
Dental radiometers may not always be accurate, but they are good for monitoring your curing light
Просмотров 912 месяца назад
Dental radiometers may not always be accurate, but they are good for monitoring your curing light
Measuring Power using the Bluephase Meter II
Просмотров 662 месяца назад
Measuring Power using the Bluephase Meter II
Fluorescence in Composites
Просмотров 294 месяца назад
Fluorescence in Composites
Bluephase PowerCure vs. Monet Beam Dispersion
Просмотров 504 месяца назад
Bluephase PowerCure vs. Monet Beam Dispersion
The Hubble
Просмотров 634 месяца назад
The Hubble
Cementation
Просмотров 1716 месяцев назад
Cementation
Measuring the PowerCure on the checkUp and Bluephase Meter II
Просмотров 959 месяцев назад
Measuring the PowerCure on the checkUp and Bluephase Meter II
Composites cannot be condensed. Take care when filling a cavity.
Просмотров 2129 месяцев назад
Composites cannot be condensed. Take care when filling a cavity.
Battery Safety
Просмотров 4810 месяцев назад
Battery Safety
Measuring the Valo X on the checkUP
Просмотров 19810 месяцев назад
Measuring the Valo X on the checkUP
Tips when choosing a curing light
Просмотров 34910 месяцев назад
Tips when choosing a curing light
Why bulk filling a cavity using resin with a POOR technique is a really bad idea!
Просмотров 18810 месяцев назад
Why bulk filling a cavity using resin with a POOR technique is a really bad idea!

Комментарии

  • @user-xy4um6bs1e
    @user-xy4um6bs1e 4 дня назад

    Is there any block out needed around gingival margins? So not to iritare gumline of patient? Or is that a simple chair side adjustment? Thank you fornthe great video!

    • @CuringLights
      @CuringLights День назад

      In cases of severe undercuts, maybe. It is a case-by-case situation. No blockout is required usually.

  • @vishwasnegi5184
    @vishwasnegi5184 13 дней назад

    What is a composite?

    • @CuringLights
      @CuringLights 11 дней назад

      It is a white dental filling

  • @izenkitt1750
    @izenkitt1750 15 дней назад

    Interesting information

  • @CuringLights
    @CuringLights 24 дня назад

    Caleb: Good point, but many amalgam users think you can pack a composite ike an amalgam. You cannot. This is why I like to use heated compules of composite, incrementally placed and adapted, but then bulk cured.

  • @calebgray6232
    @calebgray6232 24 дня назад

    This is an interesting video, but I'd like to see the demonstration redone with less initial composite and a more appropriately sized condenser. I feel like most people would take a smaller first increment and really focus not so much on compacting the composite but pushing it down into all the preps line angles

  • @vijaysankarkn9177
    @vijaysankarkn9177 Месяц назад

    Thanks for sharing!! Materials that are compatible and cured under UV, won't be compatible with visible light.

    • @CuringLights
      @CuringLights 26 дней назад

      That is correct. The light MUST be at the correct wavelength.

  • @Mary-cq7uc
    @Mary-cq7uc Месяц назад

    I have a question dr

  • @Mary-cq7uc
    @Mary-cq7uc Месяц назад

    Dr, like your content very much

  • @_PhungucToan
    @_PhungucToan Месяц назад

    Hello i'm live in Việt Nam. I can't buy that material. Can you tell me what is name of this matirial. I can't find the same matirial in Việt Nam.

  • @rafae461
    @rafae461 Месяц назад

    Quais os aparelhos testados?

  • @rafae461
    @rafae461 Месяц назад

    Quem fez este vídeo?

  • @herrzyklon
    @herrzyklon Месяц назад

    Hello, thank you for putting out these videos. I just finished my PhD and was pleased to reference you a number of times. I have a question though. I used the Bluephase to measure the output of my LCU, which was a BASE290 from BA International. It's dual peak. I was getting different readings for every subsequent push of the button. Do you know why that might have happened?

    • @CuringLights
      @CuringLights Месяц назад

      No idea, was it in ramp mode, were you measuring power or irradiance?

    • @herrzyklon
      @herrzyklon Месяц назад

      @@CuringLights hello, thanks so much for replying. It wasn't in ramp mode, it was in full power mode (3000 mW/cm^2 peak), and I was primarily measuring irradiance. I measured over 200 consecutive 5 second cycles, each at full power, with a pre-set (by the LCU) rest between cycles of 5 seconds. Irradiance dropped off sharply for the first dozen cycles (from memory) before the drop was a few tens of mW/cm^2. The battery only lasted long enough to measure 200 cures. Total drop was about 10%

    • @CuringLights
      @CuringLights Месяц назад

      @@herrzyklon : Sounds right.

  • @DrTanujKumar
    @DrTanujKumar 2 месяца назад

    Sir.. Can we use a layer of flowable composite in stead of a bonding agent as uncured resin before placing a second layer of packable composite?

    • @skane8
      @skane8 2 месяца назад

      That is what I would do. Why use bonding agent?

  • @DrTanujKumar
    @DrTanujKumar 2 месяца назад

    thank you sir for sharing your knowledge,

  • @DrTanujKumar
    @DrTanujKumar 2 месяца назад

    Amazing Video sir. thank you for sharing.

  • @MuayThaiTailandia7
    @MuayThaiTailandia7 3 месяца назад

    Who do this in Thailand ?

  • @larrystradeski8261
    @larrystradeski8261 3 месяца назад

    Doesn't heating the scalpel wreck the blade.We use a device similar to an electric hand held soldering iron.

  • @user-vn2tb6ev7b
    @user-vn2tb6ev7b 4 месяца назад

    what is the cellophane used for? what does this do?

    • @CuringLights
      @CuringLights 4 месяца назад

      Smoothing the material and improve the adaptation. It seems to work.

  • @anas-shommakhi
    @anas-shommakhi 5 месяцев назад

    Just one question , if I heated the composite , will there be a pulp inflammation due to heat or not ????

    • @mohammedmahdialshammari7006
      @mohammedmahdialshammari7006 5 месяцев назад

      Its gonna be warm enough to flow better but not that hot that it would cause a pulpal reaction

  • @lesterlorio7675
    @lesterlorio7675 5 месяцев назад

    What about the test of these curing lights?

  • @oroniisfamukta6823
    @oroniisfamukta6823 5 месяцев назад

    Hello, I recently had the opportunity to explore your RUclips channel. I must say that I am impressed with the quality of content you are creating. Your video doesn't have a good Thumbnail. it has come to my attention that the title description, video tag, video SEO and high-volume keywords are not included ―This is why you don't get much more views from your content . I also saw in your videos that your videos are not S.E.O friendly (Search Engine Optimization) while you upload video. If you want I can send you a audit file of your channel issues. Thanks and Regards Mukta

  • @essidmedamine8130
    @essidmedamine8130 5 месяцев назад

    No silane ?

  • @zorankalina4399
    @zorankalina4399 8 месяцев назад

    Hm.....what if you use 1 second light for 3/ 5 times.....allso, from diferent angels. Sure, with few seconds of pause...cos, we do not wish to burn the nerv?!? Is it still so bad...ore become a winer? Allso, G4 have to small aperture/ 8mm....and can not cower biger area,which will cose a problems with ununique polimerisatione.

    • @CuringLights
      @CuringLights 8 месяцев назад

      Well, it all depends on the light output. Let's say you use a light that delivers 1,500 mW/cm2 for 10s. Then you will deliver 15 J/cm2 of energy. If your light delivers 3,000 mW/cm2 then you would have to use it for at least 5 s to deliver the same amount of energy. Unfortunately, dental composites do not obey exposure reciprocity, so you actually have to deliver more energy as the irradiance goes up. Start curing from angles, even less energy is delivered. Simple physics and simple chemistry. Sorry to burst the bubble on fast curing.

  • @Isaac-xn5rm
    @Isaac-xn5rm 8 месяцев назад

    Does anybody know can I use the same type of material for dentq laboratory dental vacuum forming molding 110v machine it’s same function machine. But I noticed retainers and mouth guards are a bit of different material. Please if anybody has answer I’d appreciate it.

  • @rafae461
    @rafae461 9 месяцев назад

    Estou no Brasil, ansioso pelos resultados

  • @quintushiguera7105
    @quintushiguera7105 9 месяцев назад

    P R O M O S M

  • @ZACY1234
    @ZACY1234 10 месяцев назад

    Hello Dr. Price. Can you please measure the woodpecker o-star curing light as well?

  • @Rancipod
    @Rancipod 10 месяцев назад

    Excellent! Beam Collimation and homogeneity are also important features that matter in LCU quality

    • @CuringLights
      @CuringLights 7 месяцев назад

      I agree, as well as delivering a good irradiance at 8 mm distance.

  • @CuringLights
    @CuringLights 10 месяцев назад

    A multi-peak curing light will photo-cure all resins.

  • @ZACY1234
    @ZACY1234 10 месяцев назад

    Hello Dr. Price! Thank you for all these great videos. I have one question regarding this video. What is the positive of having a multi-pick curing light ?

    • @CuringLights
      @CuringLights 7 месяцев назад

      It will cure all resins, but it must be well designed, otherwise it will be spectrally non-uniform across the light tip.

  • @anderswullt6652
    @anderswullt6652 10 месяцев назад

    - very good Dr Price ......................................................................(and ther´s Bud Light)

  • @verityclubhindi
    @verityclubhindi 10 месяцев назад

    I find your content to be highly informative and engaging.❤ As a professional video editor and social media account manager, I believe I can offer valuable services that align with your goals. Would you be interested in exploring a potential collaboration?

  • @Sztyepadzso
    @Sztyepadzso 11 месяцев назад

    I want to say thank you fot this video! With the help of this video, I was able to make my own guard. My 1st pair (a thinner and a thicker one) was 50€ in 2013. Now I should pay 400€. I have made my 1st guard already. Now cost ~2€/pc.

  • @CuringLights
    @CuringLights 11 месяцев назад

    WOW, there are some really bad lights out there. Honestly, I am shocked. No wonder the median life expectancy for a posterior composite is 6-7 years.

  • @ZACY1234
    @ZACY1234 11 месяцев назад

    👍👍🙌🙌 Looking forward to the results of the test. Really curious to see how the woodpecker lights compare to the valo and bluephase !

  • @biologiabucal
    @biologiabucal 11 месяцев назад

    Please let us know your conclusions 📝😀 I will be waiting for new fresh information about emerging curing light brands!

  • @lauraglowe0611
    @lauraglowe0611 Год назад

    What’s the tickness of the material

  • @SGTCastr0
    @SGTCastr0 Год назад

    What if the customer has two front teeth missing ?

    • @CuringLights
      @CuringLights 10 месяцев назад

      No problem. Just make it without the teeth.

  • @dongdongdong8413
    @dongdongdong8413 Год назад

    Thank you master

  • @dongdongdong8413
    @dongdongdong8413 Год назад

    Thank you master

  • @camillamiskovich7344
    @camillamiskovich7344 Год назад

    What material and size do you use?

  • @standingMMA
    @standingMMA Год назад

    Where can i get all the machines

  • @keithhollanderdds7015
    @keithhollanderdds7015 Год назад

    It would seem that using flowable in the bottom of the box would address the flow and void issues, like in a PVS imression. Also using a big increament in the initial example and then using the unidose tip in the warmed example is not exactly apples to apples.

    • @CuringLights
      @CuringLights Год назад

      Agreed. But It is not my idea: Seewww.ncbi.nlm.nih.gov/pubmed/12540112 Some call it the snow-plow technique

  • @djennings-DDS
    @djennings-DDS Год назад

    Very interesting! I’d be intrigued to see what the MOD mold would look like after trans-enamel polymerization

    • @CuringLights
      @CuringLights Год назад

      As you know, dentists should not rely on trans enamel polymerization, it will certainly help, but totally unreliable. pubmed.ncbi.nlm.nih.gov/32053462 pubmed.ncbi.nlm.nih.gov/11203991 'transmitted irradiance decreases exponentially with tooth struc- ture thickness and is lowered to insignificant values in 3-mm-thick tooth walls'

  • @edwarcaiado2610
    @edwarcaiado2610 Год назад

    How much $$ ??

  • @patrickroetzer5189
    @patrickroetzer5189 Год назад

    Well done Richard

  • @tiagoomuller
    @tiagoomuller Год назад

    Hi Dear, previsão para vendas no Brazil?

    • @Dr.Bernardo
      @Dr.Bernardo Год назад

      Novembro. Deve chegar por volta de 12k

  • @amirmo6615
    @amirmo6615 Год назад

    Thank you What is the purpose of putting 45 degree bevel around the border?

    • @CuringLights
      @CuringLights Год назад

      It is more comfortable to the patient instead of a sharp ledge